Compact Mass Spectrometer (ESI, APCI/TLC/MS), Advion, USA.
Mass spectrometry’s characteristics have raised it to an outstanding position among analytical methods: unequalled sensitivity, detection limits, speed and diversity of its applications. Most applications are oriented to proteomic, metabolomic studies, drug discovery and metabolism. In addition to other applications such as pollution control, food analysis and forensic medicine.
Specifications
Advion compact mass spectrometer (CMS) is provided with the following specification:
- Ion Source: ESI, APCI, or APCI/ASAP
- Polarity: Positive & negative ion switching in a single analysis
- Flow Rate Range:
- ESI: 10 µL/min to 1 mL/min
- APCI: 10 µL/min to 2 mL/min
- m/z Range:
- expression S m/z 10 to 1,200
- expression L m/z 10 to 2,000
- Acquisition Speed: 10,000 m/z units/sec
- Sensitivity (ESI): 10 pg reserpine (FIA – 5 µL injection at 100 µL/min) 100:1 S/N (RMS) with SIM of m/z 609.3
- Accuracy: ±0.1 m/z units of the entire acquisition range
- Stability: 0.1 m/z units at m/z 1,200 over 12 hour period operating temperature of 20ºC ±1ºC
- Polarity Switching Speed: 50 ms
- Dynamic Range: 4.5 orders of magnitude
Applications
The expression CMS integrates with almost every chemistry method from the simplest, fastest direct probe analysis needing no sample preparation to ultra-high-performance compound separation with LC integration. The expression CMS offers the most versatile sample methods on the market, including/ but not limited to:
Reaction Monitoring
- Compound identification for batch and flow chemistry
- Confirm identity and purity quickly and accurately
Monitoring of metabolites
- Preliminary screening and prioritization of plant extracts through detection of major constituents (confirmation of proposed identity)
- Detection of metabolites in biotransformation and microbial transformation of drugs
- Detection of degradation products of drugs.
Available injection Interfaces
- TLC
- ASAP (Probe) available only with ACPI mode
- Direct injection
Anonymous (verified owner) –
Aya Hosny (verified owner) –
Thank you so much
Mariam Ghanem (verified owner) –
the work is well organized. Thanks a lot , just keep going
Eman Abd AL Mageed (verified owner) –
islam mohamed (verified owner) –
Rabaa M. Khaled (verified owner) –
Ghada Abbas (verified owner) –
Mai Emad (verified owner) –
Rabaa M. Khaled (verified owner) –
islam mohamed (verified owner) –
Aya H. (verified owner) –
ebtesam taha (verified owner) –
Many thanks to dr/shereen mamdouh and dr/loay for their helpness and kindness.They are very special and highly qualified persons to work with them🌹🌹🌹🌹🌹.
Thanks to all team of work
Walid Amir (verified owner) –
ebtesam taha (verified owner) –
Many thanks
Iman (verified owner) –
Easy and quick instrument to determine the ESI of the compounds.
Yara (verified owner) –
Organized system, sharp dates and qualified staff
Nada (verified owner) –
Anonymous (verified owner) –
Thanks alot for your speed and quality of the analysis, special thanks for Dr. Shereen for her kind attention and help.
Ebtisam taha (verified owner) –
Many Thanks to dr mohamed dawood and dr loay for your help, kindness, speed, kind attention and high quality analysis
nada.mohamed (store manager) –
Thank you for your comment and we did put your comment into our consideration.